36
Upload New Events Only
This selection will allow you to upload only new events that have occurred since
the last time the event buffer was uploaded. These events can then be appended
to the event buffer file to create a continuous file of events on the event buffer.
Upload Last 16 Events
This selection will allow you to upload the 16 most recent events in the event buffer.
This function does not affect the “new event” status of events in the panel. If the last
16 events are new events, they will still be considered new events the next time the
event buffer is uploaded. Note that the last 16 events cannot be saved or appended.
Print Event Buffer
Selecting this option will allow the event buffer to be printed on a printer
connected to the computer. When selected, you will be given the option of
printing the Uploaded Event Buffer, the Event Buffer on File, or the last 16 events.
Selecting “Event Buffer on File” will print the event buffer that has been saved
in the computer’s memory using the Save Event Buffer option. Selecting “Last
16 Events” will print the last 16 events stored in the event buffer.
View Saved Event Buffer
Selecting this option will display the contents of the event buffer file that has been
created using the Save Event Buffer option.
Save Event Buffer
Selecting this option will save the uploaded event buffer to a file on your disk drive.
The event buffer files on your disk drive will have the same name as the Work File
name, but with a different extension. For example, if your Work File is called
PC4000.DSC, the Event Buffer File will be named PC4000.BUF.
You will be asked to either Save or Append the Event Buffer file. When the event
buffer is
Saved
to a file, any information already in the file will be overwritten. If the
event buffer is
Appended
to the file, new events in the event buffer are attached
to the end of any previous information already saved to your Event Buffer File.
When viewing an appended Event Buffer File, the two event buffers are
separated by a highlighted “Event Buffer Appended” message. The date and
time shows when the event buffer was appended.
Initialize Modem
Selecting this option will re-initialize the modem using the current defaults
including the setting stored in the Modem Command File (MODEMSTR.FIL). Use
this feature if the software is unable to automatically re-initialize the modem.
Terminate Call / Hang Up
Select this option to terminate the call to the panel. Since the panel and the modem
will stay on-line after the first communication, you may wish to hang up the call
while while you edit the work file. When you are ready to download the edited
Workfile to the control panel, you may call the panel again and reconnect.
Exit From This Menu
Selecting this option will return you to the edit screens, allowing you to make
changes or examine the Work File. Selecting this option will not hang up the modem
and the control panel. To hang up, you must select “Terminate Call/Hang Up”.