Set Panel Time and Date
When selected, the time and date on the control panel may be changed. Enter two
digits each for the day, month, year, hour and minutes. You can also update the
panel's time and date with the time and date settings from your computer. To ensure
the panel is updated as accurately as possible:
1. Make sure your computer has the correct time and date.
2. Make sure your computer is connected to the control panel.
3. Press [S] to update the panel.
Quick Exit (PC40X0 only) Auto-Arm
Quick Arm (PC40X0 only) Door Chime
Schedule Arm (PC40X0 v2.x only)
Schedule Disarm (PC40X0 v2.x only)
A menu will appear for each of these items to allow you to enable or disable the
features. A second menu will appear for each item to determine on which partitions
the features will be enabled or disabled. An arrow will indicate which partitions are
selected. Select the “execute” command to download the changes to the control
panel.
Bell Test
This option will sound the bell at the premises for a period of 2 seconds. Bell outputs
are any outputs (BELL terminals on the main panel; Switch Auxiliary Outputs and all
PGM outputs) that are programmed for Fire and Burg, Inv Fire and Burg, Burg Only,
Inv Burg Only, Fire Only and Inv Fire Only.
A window will allow you to select which partitions to test. An arrow will indicate the
selected partitions. After selecting the partitions to test, select the “execute” command
to download the test command to the control panel.
Lamp Test (PC40X0 v2.x only)
This option will turn on all PC4216 outputs that are set to be lamp test eligible when
enrolled. This is done in order to test the wiring, to ensure that the outputs are in proper
working order.
Beep Keypad
This option will cause the keypads on the premises to beep rapidly 16 times. A
window will allow you to determine in which partition or partitions the keypads will
beep. An arrow will indicate the selected partitions. Global Keypads will beep no
matter which partition is selected.
After selecting the partitions, select the “execute” command to download the beep
command to the control panel.
This feature is useful for alerting staff or clients on the premises that downloading
has been completed
Utility Output
This option will activate, by partition, all outputs (Main Bell, SW Aux., PGM outputs)
that are programmed for the “Utility Output” option.
A window will appear to allow you to determine in which partition or partitions the
utility outputs will be activated. An arrow will indicate the selected partitions; after
selecting the partitions, select the “execute” command to download the test
command to the control panel.