PC3000, PC2585, PC2550, PC2525, PC1550, PC1500, PC1150,
PC560, PC550, DSC8400 and WLS900 Status (DUC) Menus
Pressing [F4] when in the “Edit a File” screens will automatically display the status
page and the “Status Download/Upload Control” menu.
Continuous Update Feature
The continuous update feature allows you to constantly monitor the status of the
panel. When selecting any of the status upload selections in the status D.U.C menu,
you will be prompted as to whether you wish to enable this feature. When this function
is active, the computer will constantly monitor whatever status you have chosen to
upload (either global status upload or any selected item), and it will update the status
screen accordingly until you press [ESC] to cancel the upload or until an alarm is
detected. The frequency of the screen update depends on which status you have
selected to upload (i.e. the more items selected for upload, the less the screen update
frequency).
Global Status Upload
This function will upload the entire status of the panel, changing the values in the
customer Work File. The status in the Work File is not valid until this function is
prompted.
Upload Selected Status
Selecting this function will display a second menu in which you can select which
status items you wish to upload. The rest of the status will not be uploaded and thus
is not valid. This function is useful when you only want to see the status of a particular
section. With this function you can enable the continuous update feature as described
above.
NOTE:
Not available for DSC8400.
Arm / Disarm Control
This function will produce another menu with which you can select to arm or disarm
the panel. The panel will beep three times and wait the duration of the exit delay before
arming. The panel will not arm if zones are in violation; and a zone violation error will
be displayed. In this event, a message will appear explaining the panel can not be
armed. After arming or disarming the panel, the computer will check that the panel
did in fact arm or disarm and upon hanging up, will send the appropriate arm/disarm
code to the central station if programmed to do so.
NOTE:
Not available for DSC8400.
Bypass Zones
This function will produce another menu in which you can select to bypass any
number of individual zones or clear all bypassed zones. Use the cursor up and down
keys to move to the line (zone) you wish to tag. With the cursor on the desired zone,
press the [Space] bar to tag that zone. Continue moving the cursor and tagging zones
as desired. To clear all bypass zones tag the “Clear all Bypasses” selection only.
Once you have made your selections press [ENTER] to initiate the operation.
NOTE:
Not available for DSC8400.
You cannot clear all bypasses and bypass a zone in one operation.