46
Sensor Reset
This option will activate, by partition, all outputs (Main Bell, SW Aux., PGM outputs)
that are programmed for the “Sensor Reset” option.
A window will appear to allow you to determine in which partition or partitions the
sensor reset will be activated. An arrow will indicate the selected partitions; after
selecting the partitions, select the “execute” command to download the reset
command to the control panel.
Combus Reset (PC40X0 only)
This option is used to re-initialize communications between the main panel and the
modules by removing power from the modules to reset them. Special note when
using Combus Reset on a PC4000 Control Panel only: a Combus reset will
terminate the connection between the panel and the downloading computer.
Send LCD Message
Use this option to send a message to display on the LCD keypads installed on the
premises. When selected, a window will allow you to enter a 32 character message (2
lines of 16 characters each). Type the message and press [ENTER].
On PC40X0 files, a window will allow you to determine which partition or partitions
will display the message on the LCD4500 keypads. An arrow will indicate the
selected partitions. After selecting the partitions, select the “execute” command to
download the message to the control panel. The message will be displayed on all the
keypads assigned to the designated partitions.
The message will be displayed when the partition is disarmed. The message will be
erased after the partition has been armed and disarmed three (3) times. If another
message is downloaded to the control panel, the new message will immediately replace
the first. The message is erased from Global Keypads only after all partitions to which
the message was sent have been armed and disarmed three times.
On (PC5015, PC5010, PC5008, PC1575/1580, PC1565-2P, PC1555/1565 and PC580/
585 files only) panels, the message will be displayed after 30 seconds of inactivity (i.e.
no keypresses) on each LCD keypad. The message can be cleared from the keypad
display by pressing any key. It will then re-appear after 30 seconds of inactivity on the
keypad. The message will be erased after having been cleared from the keypad the
number of times programmed in the panel. If another message is downloaded to the
control panel, the new message will immediately replace the first message.
Special Message (PC40X0 only)
This option is used to enable or disable the special message feature for each of the
partitions on the PC4020 / PC4010 / PC4000. Special messages are the two
messages the installer can program for the user. They are the Fail to Arm message
and the Alarm When Armed message.
Remote Operation (PC4020 and PC4010 Only)
This option is used to enable or disable outputs programmed for remote operation.
Reset Latching Tamper (PC5015, PC5010, PC5008, PC4020 v2.x,
PC4010 v2.x, PC1575/1580, PC1565-2P, PC1555/1565 or PC580/
585 files only)
This option is used when the system uses Double End-of-Line Resistor Zones and the
Tamper Inhibit Arming option is enabled or if the system has 24-hour Latching Zones.
Selecting “Reset Latching Tamper” will reset the tamper condition and allow the affected
partition to be armed as if installers programming had been entered from a keypad.