Initialize Modem
This function will re-initialize the modem to the current defaults including whatever was
entered into the Modem Command File (MODEMSTR.FIL). This is useful if for some
reason the connection with the panel was broken (e.g. if the modem power cord
became unplugged) and the software is unable to automatically re-initialize the
modem. When you have fixed the problem, making this selection should allow the
modem to re-initialize allowing you to reconnect to the panel.
Terminate Call / Hang Up
Once editing is complete, this function will hang up the call to the panel. Since the
panel and the modem will stay on-line after the first communication, you may wish to
hang up the call while changes are being made to the Work File and reconnect when
you are ready to upload or download the Work File to the panel.
DC1664, P-16, P-1664 Status (DUC) Menus
Selecting the Status menu item will display the Status Download/Upload Control
Menu. This selection allows you to upload and control the status of the system.
Global Status Upload
This function will upload the entire status of the panel. The status in the Work File is not
valid until this function is selected.
Selected Status Upload
This function is for uploading individual items. When this function is selected, a
Selected Status Upload Menu will be displayed so that you may indicate which item
to upload. The following items may be uploaded:
Zone Status
Uploads the current open/closed status of each zone. An “O” will be displayed
beside the zone number if a zone is open. If a zone is open, the Bypass Status
will also be uploaded.
Arm/Disarm
Uploads the armed status of Groups A through D. “No” indicates that a group is
disarmed; “Yes” indicates that a group is armed.
Alarm Memory
Uploads the Alarm Memory of each zone. An “M” will appear beside the zone
number of the zones that are in alarm memory.
Bypass/History
Uploads the Bypass Status and Bypass History of each zone. A “B” will appear
beside zones that are presently bypassed; an “H” will appear beside zones that
are in Bypass History.
Quick Arm (DC1664 only)
Uploads the enabled status of the Quick Arm feature.
Door Chime
Uploads the enabled status of the Door Chime feature for each zone. A “D” will
appear beside the zones that have the Door Chime feature enabled.
Auto-Arm Schedule
Uploads the Auto-Arm times and the day assignments programmed in the three
Auto-Arm schedules.